Volume Two 5. Urban Residential 1 & 2 Zone [R] 5.1.26. Discharge of contaminants to air within the Blenheim Airshed from the burning of solid fuel in a small scale solid fuel burning appliance that is up to 15 years of age (except an enclosed pellet burner), or an enclosed pellet burner of any age installed prior to 9 June 2016. [R] 5.1.27. Discharge of contaminants to air within the Blenheim Airshed from the burning of solid fuel in a small scale solid fuel burning appliance installed after 9 June 2016. [D] 5.1.28. Grazing of livestock for maintenance of undeveloped land. [D] 5.1.29. Farming on a Computer Register in the Urban Residential 2 Greenfields Zone prior to the part or full development of the site for residential activity. [D] 5.1.30. Emergency service activities of the New Zealand Fire Service on Secs 10 and 12 Blk XIV TN of Seddon (Seddon Fire Station), Lot 1 DP 5124 (Ward Fire Station) and Sec 234 Town of Havelock (Havelock Fire Station). 5.2. Standards that apply to all permitted activities 5.2.1. Construction and siting of a building or structure except a temporary building or structure, or an unmodified shipping container (unless any Standards listed below are specified as Standards for those activities). 5.2.1.1. Within the Urban Residential 1 Zone, the construction or siting of a dwelling must be on a Computer Register with a net site area no less than 290 m. 2 5.2.1.2. Within the Urban Residential 1 Zone, the construction or siting of a dwelling on land must meet the following access requirements: (a) access for one dwelling must be a minimum width of 3.0m; (b) access for two to four dwellings must be a minimum width of 3.5m and a minimum sealed width of 3.0m; (c) access for five to six dwellings must be a minimum width of 6.0m and a minimum sealed width of 5.0m. 5.2.1.3. No more than one residential dwelling must be construction or sited per Computer Register within the Urban Residential 2 Zone. 5.2.1.4. In the Urban Residential 2 Zone, permanent buildings must not cover more than 45% of the net site area. 5.2.1.5. The maximum height of a building or structure must not exceed 7.5m. 5.2.1.6. No part of a building must exceed a height equal to the recession plane angle determined by the application of the Recession Plane and Height Controls in Appendix 26. The recession plane angle must be measured from a starting point 2m above ground level at the property boundary. 5.2.1.7. Any part of a wall of a dwelling must be setback a minimum of 1m from the property boundary. 5 – 3