Volume Two 6. Urban Residential 3 Zone (b) have direct contact with the main indoor living area through an external door; (c) not include driveways, parking spaces or buildings but may include decking; (d) have a slope of no more than 5 degrees in any direction. 6.2.1.8. A front entrance garage or other non-habitable accessory building must be setback a minimum of 1m behind the main face of the dwelling; except where the dwelling is setback 10m or more from the road frontage. 6.2.1.9. Notwithstanding Standard 6.2.1.8, a garage must be set back a minimum of 5m from any road frontage; except that a side entrance garage with a window on the wall facing the road must be set back a minimum of 2m from the road frontage. 6.2.1.10. The height of a fence or part of a fence must not exceed 2m. 6.2.1.11. The height of a fence or any part of a fence on a boundary between the Urban Residential 3 Zone and any land zoned Open Space 1 or Open Space 2 must not exceed 1.2m. 6.2.1.12. A building or structure constructed or sited, or any trees planted, must be set back a minimum of 8m from the bank of a river, Drainage Channel Network or the landward toe of a stopbank. 6.2.1.13. A building or structure in which human effluent will be created must connect to and dispose of its effluent into a Council operated sewerage system designed for that purpose, if the system is within 30m of the property boundary or 60m of the closest building. 6.2.2. Noise. 6.2.2.1. The activity must not cause noise that exceeds the following limits at the zone boundary or within the zone: 7.00 am to 10.00 pm 50 dBA L Aeq 10.00 pm to 7.00 am 40 dBA L Aeq 70dBL AFmax 6.2.2.2. Noise must be measured in accordance with NZS 6801:2008 Acoustics – Measurement of Environmental Sound, and assessed in accordance with NZS 6802:2008 Acoustics – Environmental Noise. 6.2.2.3. Construction noise must not exceed the recommended limits in, and must be measured and assessed in accordance with, NZS 6803:1999 Acoustics – Construction Noise. 6.2.3. Use of external lighting. 6.2.3.1. Light spill onto an adjoining residential site must not exceed 2.5 Lux spill (horizontal and vertical). 6.2.4. Odour. 6.2.4.1. The odour must not be objectionable or offensive, as detected at or beyond the legal boundary of the area of land on which the permitted activity is occurring. 6.2.5. Smoke. 6.2.5.1. The smoke must not be objectionable or offensive, as detected at or beyond the legal boundary of the area of land on which the permitted activity is occurring. 6 – 3