11. Business 3 Zone Volume Two 11.2.1.4. The minimum setback of a building from the boundary of any adjoining zone must be 8m. 11.2.1.5. The height of a fence, or part of a fence, must not exceed 2m. 11.2.1.6. Large format retail tenancy areas must have a gross floor area greater than 1000m². 11.2.1.7. A building or structure in which human effluent will be created must connect to, and dispose of its effluent into, a Council operated sewerage system designed for that purpose, if the system is within 30m of the property boundary or 60m of the closest building. 11.2.1.8. Metal cladding, roofing or fences are painted or otherwise coated with a non-reflective finish. 11.2.2. Noise. 11.2.2.1. An activity must not cause noise that exceeds the following limits at the zone boundary or within the zone: 7.00 am to 10.00 pm 60 dBA L Aeq 10.00 pm to 7.00 am 55 dBA L Aeq 75dBL AFmax 11.2.2.2. An activity must not cause noise that exceeds the following limits at the boundary of, or within, any land zoned Urban Residential 1, Urban Residential 2 (including Greenfields) or Urban Residential 3 or within the notional boundary of a dwelling within any other zone: 7.00 am to 10.00 pm 50 dBA L Aeq 10.00 pm to 7.00 am 40 dBA L Aeq 70dBL AFmax 11.2.2.3. Noise must be measured in accordance with NZS 6801:2008 Acoustics – Measurement of Environmental Sound, and assessed in accordance with NZS 6802:2008 Acoustics – Environmental Noise 11.2.2.4. Construction noise must not exceed the recommended limits in, and must be measured and assessed in accordance with NZS 6803:1999 Acoustics – Construction Noise. 11.2.3. Use of external lighting. 11.2.3.1. All exterior lighting must be directed away from adjacent properties, roads and any adjoining site within the Urban Residential 2 Zone so as to avoid any adverse effects on the neighbourhood and/or traffic safety. 11.2.3.2. Light spill, when measured at a height of 1.5m above the ground at the zone boundary, must not exceed 8 Lux spill (horizontal and vertical). 11.2.4. Outdoor storage. 11.2.4.1. An outdoor storage area must be screened with a wall or fence 1.8m high or dense planting of vegetation capable of growing to 1.8m high. 11.2.5. Odour. 11.2.5.1. The odour must not be objectionable or offensive, as detected at or beyond the legal boundary of the area of land on which the permitted activity is occurring. 11.2.6. Smoke. 11.2.6.1. The smoke must not be objectionable or offensive, as detected at or beyond the legal boundary of the area of land on which the permitted activity is occurring. 11 – 2