Volume Two 12. Industrial 1 and 2 Zones 12.2.2.2. An activity must not cause noise that exceeds the following limits at the boundary with, or within, any adjacent Business 1 or 2 Zone: 7.00 am to 10.00 pm 60 dBA L Aeq 10.00 pm to 7.00 am 55 dBA L Aeq 75dBL AFmax Standards for the Industrial 2 Zone only: 12.2.2.3. An activity must not cause noise that exceeds the following limits at the zone boundary or within the zone: At any time 75 dBA L Aeq 85dB L AFmax Standards for both Industrial 1 and 2 Zones: 12.2.2.4. An activity must not cause noise that exceeds the following limits at or within any adjacent land zoned Urban Residential 1, Urban Residential 2 (including Greenfields) or Urban Residential 3, or within the notional boundary of a dwelling in any adjacent zone (except Industrial 1 or 2 Zones): 7.00 am to 10.00 pm 50 dBA L Aeq 10.00 pm to 7.00 am 40 dBA L Aeq 70dB L AFmax Exception: Where Lots 16 to 20 DP 348832 and Lot 2 DP 352510 adjoin Urban Residential 2 Zone, the noise limits for Industrial 1 in 12.2.2.1 and 12.2.2.2 apply. 12.2.2.5. Noise must be measured in accordance with the provisions of NZS 6801:2008 Acoustics – Measurement of Environmental Sound, and assessed in accordance with NZS 6802:2008 Acoustics – Environmental Noise. 12.2.2.6. Construction noise must not exceed the recommended limits in, and must be measured and assessed in accordance with, NZS 6803:1999 Acoustics – Construction Noise. 12.2.3. Use of external lighting. 12.2.3.1. All exterior lighting must be directed away from adjacent properties and roads so as to avoid any adverse effects on the neighbourhood and/or traffic safety. 12.2.3.2. Light spill onto an adjoining property within the same Industrial Zone, measured 2m inside the boundary of the adjoining property, must not exceed 10 Lux spill (horizontal and vertical). 12.2.3.3. Light spill onto an adjoining site that is zoned Urban Residential 1, Urban Residential 2 (including Greenfields), Urban Residential 3, Industrial 1 or Industrial 2 must not exceed 2.5 Lux spill (horizontal and vertical). 12.2.4. Storage of goods outdoors. 12.2.4.1. An outdoor storage area must not be located within: (a) 3m of a road boundary; (b) 3m of the boundary of any property within a different zone, unless the other zone is Industrial 1, Industrial 2, Urban Residential 1, Urban Residential 2 (including Greenfields) or Urban Residential 3; (c) 3m of the boundary of Lots 16 to 20 DP 348832 and Lot 2 DP 352510; 12 – 5