20 March 2014 Chapter 39 - District Recreation Zone 39.1.2.3 Noise 39.1.2.3.1 All permitted activities shall be conducted so as to ensure that noise arising from such activities shall not exceed the following noise limits at any point on the boundary of the District Recreation Zone. • 0800 hours - 2200 hours Monday to Friday, and 55 dBA L10 • 0800 hours - 2200 hours Saturday • On any day between 0800 hours - 2200 hours No L max limit • At all other times including any public holiday 45 dBA L10 and 75 dBA L max 39.1.2.3.2 Provided these noise limits shall not apply to activities of a normal recreational nature, such as sporting events, that do not involve motor sport or amplified music. 39.1.3 Discharges 39.1.3.1 Domestic Wastewater Management Provision must be made for the satisfactory management of all domestic wastewater in accordance with the requirements of the Plan. The requirements of the Plan are deemed to have been met where all domestic wastewater is connected to a public system expressly designed for this purpose or the conditions for on-site domestic wastewater discharges (Rule 39.1.3.2) are met. 39.1.3.2 The discharge of domestic wastewater into land The discharge of domestic wastewater, through any on-site wastewater management system lawfully established without resource consent prior to 21 April 2005, into land is a Permitted Activity providing: 39.1.3.2.1 A public sewer is not located within 30 metres of the lot boundary or 60 metres of the closest building on the lot to be serviced. 39.1.3.2.2 Garbage grinders are not installed in any building that the on-site wastewater management system services. 39.1.3.2.3 The rate of discharge does not exceed 2000 litres per day, averaged over any one week period. 39.1.3.2.4 There is no increase in the rate of discharge due to an increased occupancy of the building(s) that the on-site wastewater management system serves following an extension or alteration of the building(s). 39.1.3.2.5 The domestic wastewater, following primary treatment, is able to infiltrate through at least 600mm of unsaturated soil or, following secondary treatment, is able to infiltrate through at least 300mm of unsaturated soil. 39.1.3.2.6 There is no ponding of any domestic wastewater, or no run-off or infiltration of any contaminant beyond the property boundary or into any surface waterbody, groundwater or coastal water or drainage channel. 39.1.3.2.7 The on-site wastewater management system is maintained in an efficient operating condition at all times. 39.1.3.2.8 No objectionable odours can be detected. 39 - 3