Chapter 28 - Standard Requirements • Original and final contours; • Areas of cut and fill; • Subsoil drainage; and • Silt control. 28.1.13.5.2 Roads and Services a) Plans showing the roads including everything that is to be located within the street or within the subdivision (eg; carriageways, kerbing, footpaths, berms, trees, water mains, sanitary sewers, pump stations, stormwater drains, manholes, sumps, electric power, road lights, telecommunication cables and junction boxes and transformer sites). Plans shall also show the limit of all work proposed to be done by the developer and its relationship to adjacent existing works or property; b) Longitudinal sections of every road including levels. Longitudinal sections of sanitary sewers and stormwater drains, including pipe sizes and types, design flows, manholes, and also underground services which cross the line of the longitudinal section, to show calculated clearances; c) Detailed typical road cross-sections showing the location of all features described in this document including engineering services, road formation, subgrade drainage, metalling, kerb and channelling, sealing or paving, footpaths and other walkways, berms and planting areas; d) Details showing how roads and services are to be connected to existing roads and services; e) Details showing underground cabling and services provided by others; f) Plans shall provide levels to the recognised local datum; and g) The developer is responsible for the testing and certification of water, sewerage and stormwater services. (Certification to be lodged with the Council). 28.1.13.6 ‘As-Built’ Plans Upon completion of construction, copies of ‘As-Built’ plans are to be submitted by the developer showing the following details: a) Sanitary drainage reticulatio n - including the measured positions of manholes and manhole invert levels; measurements to house connections, referred to the centre of the downstream manhole cover and the length, position and depth of laterals referred to the site; b) Stormwater drainage reticulati on - details as for sanitary drainage reticulation (refer above). The plans shall also show subsoil drainage and floodpath level information; c) Water reticulati on - including the position of mains, location of hydrants, valves, tees and connections; d) Areas of filli ng - showing the total depth of fill (certification of compaction shall be provided at the time ‘As-built’ plans are lodged); e) Duc ts - measurements to ducts installed for telephone, power and cable television reticulation; and f) Road names - as suggested by the owner and as approved by Council. 28 -9