Marlborough Sounds Resource Management Plan 26.2.9.3 Accessways into service stations shall comply with the following minimum separation distances from other driveways: a) Between driveways for residential activities 7.5 metres b) Between driveways for other activities 15 metres 26.2.9.4 The width of any driveway into a service station shall comply with the following: a) One way (with no tanker movements) 3.5 metres min 6.0 metres max b) Two way, and one way (with tanker movements) 6.0 metres min 9.0 metres max 26.2.9.5 The road boundary of the site shall be bordered by a nib wall to control traffic flows and to clearly define entrance and exit points. 26.2.9.6 Pumps shall be located a minimum of 4.5 metres from the road boundary and a minimum of 12 metres from the midpoint of any vehicle crossing at the road boundary. All vehicles shall be clear of the footpath and accessways when stopped for refuelling. 26.2.9.7 A minimum path width of 4.5 metres shall be provided for vehicles through the service station forecourt. 26.2.9.8 Tanker access to bulk tank filling positions shall ensure that tankers drive in and out in a forward direction, without the need for manoeuvring either on the site or adjacent roadways. Where this cannot be achieved, an area sufficient for tanker manoeuvring shall be provided so that the tanker may drive out in a forward direction. 26.2.9.9 Tankers discharging shall not obstruct the footpath or any part of the site intended for use by vehicles being served at refuelling positions or waiting for service. 26.2.9.10 The minimum path and loading bay widths for tankers shall be 4.5 metres with a minimum inside turning radius of 7.5 metres. 26.2.9.11 Minimum sight distances at entrance and exit points - refer Rule 26.2.4. 26 - 28